Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	41
Date	08/12/14
Start Time	10:43:01
Diameter Midpoint
 10.9	55990.6
 11.3	73086.8
 11.8	88022.3
 12.2	110220
 12.6	135622
 13.1	164873
 13.6	197688
 14.1	230868
 14.6	264083
 15.1	310531
 15.7	355257
 16.3	407457
 16.8	459237
 17.5	513399
 18.1	567477
 18.8	625764
 19.5	682257
 20.2	731063
 20.9	777791
 21.7	817508
 22.5	864905
 23.3	901114
 24.1	932276
 25.0	956018
 25.9	976824
 26.9	989006
 27.9	982652
 28.9	968904
 30.0	932731
 31.1	893009
 32.2	834018
 33.4	761953
 34.6	673035
 35.9	584319
 37.2	497821
 38.5	409483
 40.0	328903
 41.4	256794
 42.9	195075
 44.5	142031
 46.1	101828
 47.8	70318.5
 49.6	47820.2
 51.4	31603.4
 53.3	20030.4
 55.2	12640.5
 57.3	7626.91
 59.4	4912.2
 61.5	2943.59
 63.8	1897.53
 66.1	1092.11
 68.5	649.38
 71.0	466.849
 73.7	355.883
 76.4	243.357
 79.1	201.119
 82.0	152.468
 85.1	168.11
 88.2	120.541
 91.4	130.922
 94.7	131.599
 98.2	112.219
101.8	139.57
105.5	114.149
109.4	109.515
113.4	115.175
117.6	130.374
121.9	123.486
126.3	122.892
131.0	113.23
135.8	89.6693
140.7	89.3308
145.9	98.0746
151.2	67.9521
156.8	79.1053
162.5	84.6842
168.5	61.8558
174.7	59.2458
181.1	51.2953
187.7	75.7865
194.6	53.9458
201.7	53.7651
209.1	78.6739
216.7	57.0763
224.7	42.6025
232.9	44.9769
241.4	28.5294
250.3	30.2456
259.5	24.7557
269.0	43.3846
278.8	39.8272
289.0	24.6659
299.6	34.8839
310.6	34.8712
322.0	15.8652
333.8	21.6853
346.0	12.3908
358.7	9.10013
371.8	12.4308
385.4	16.583
399.5	27.3142
414.2	12.4871
429.4	13.271
445.1	0
461.4	7.32388
478.3	3.93581
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1674
High Voltage	9862.16
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	25.2572
Mean(nm)	25.9525
Geo. Mean(nm)	24.7706
Mode(nm)	26.896
Geo. Std. Dev.	1.36099
Total Concentration(#/cm)	2.1957e+007
Comment	